EDIS allows the user to set a circuit so that All Three Phases supply the same point, i.e a Three Phase or TP Circuit.
Three-phase circuit can only be set on Three Phase Boards.
Step 1: Select the Board menu option and search for the Board,
Step 2: Click on the board name to view the board circuits
Step3: Select a circuit and click on the circuit or select edit circuit
Step 4: In the Edit Circuit screen, select the correct option in the “All Three Phases Supply the Same Point” field.
This will change the circuit to a TP circuit if TP is selected, if not the circuit will remain a single phase circuit.
Step 5 : You can check the result by viewing the board schedule. Select the Board menu option and then select the PDF Schedule to download the PDF schedule.